The Amat Spa water network, Imperia.
Amat Spa has been commissioned to unify and simplify remote control systems within a plant consisting of different supervision systems installed throughout. The solution they have adopted is based on Movicon 11.
The SaiaDataMode driver has been developed to communicate with Saia-Burgess PCD series PLCs. It is a direct driver, not based on Saia libraries, making it possible to communicate in different ways:
Movicon 11 – Rel. 11.4.1.7 DBL282
Movicon 11 CE – Rel. 11.4.1.7 DBL282
The Omron Host Link Driver was designed for use with Omron PLCs. The protocol Host Link is a serial multi-point protocol of type Master/Slave. The driver plays the role of master.
Movicon 11 – Rel. 11.4.1.6 DBL282
Movicon 11 CE – Rel. 11.4.1.6 DBL282
The Hitachi Ethernet H-protocol driver supports the communication with PLCs Hitachi of EH and EHV series, equipped with a built-in Ethernet port or an Ethernet communication module.
This driver implements the task codes A0h, Read I/O (continuous address), and A2h, Write I/O (continuous address), of the Ethernet H-protocol.
Movicon 11 – Rel. 11.4.1.4 DBL282