  • In reply to: Movicon 11.X Install Problem

    26 March 2013 at 4:01 pm #21078
    Maverick
    Participant

    Hi,
    Please provide some more information, with these we can not help!
    Which Movicon version you are using? I’m using the last 11.3.1104 but i don’t have this dll.

  • In reply to: Movicon Report Designer

    26 March 2013 at 3:53 pm #21064
    Maverick
    Participant

    Hello Guys,

    My first suggestion is to work on ‘Report Designer’ with the preview button. Maybe inserting the filter in the report by specifying a ‘start date’ and an ‘end date’ for example using ‘parameters’.

    Once this is done, you can move in Movicon to retrieve  the report from a command line using the ReportViewernet.exe and the parameters or better using the same but running the command from VB code so you can use the parameters that you defined in the report.

  • In reply to: Alarms Text

    22 March 2013 at 11:22 am #21076
    Maverick
    Participant

    Hi!
    I’m using the same, normally I refer to the time reported in the email, I gave a look at the settings and it does not seem possible to change the description of the alarm. I think you can do it through VB code. If you look on the Progea site there is an example (AlarmDispatcherBasic).

  • In reply to: Alarms Text

    22 March 2013 at 11:22 am #21075
    Maverick
    Participant

    Hi!
    I’m using the same, normally I refer to the time reported in the email, I gave a look at the settings and it does not seem possible to change the description of the alarm. I think you can do it through VB code. If you look on the Progea site there is an example (AlarmDispatcherBasic).

  • In reply to: Alarms Text

    22 March 2013 at 11:22 am #21074
    Maverick
    Participant

    Hi!
    I’m using the same, normally I refer to the time reported in the email, I gave a look at the settings and it does not seem possible to change the description of the alarm. I think you can do it through VB code. If you look on the Progea site there is an example (AlarmDispatcherBasic).

  • In reply to: Alarms Text

    22 March 2013 at 11:22 am #21073
    Maverick
    Participant

    Hi!
    I’m using the same, normally I refer to the time reported in the email, I gave a look at the settings and it does not seem possible to change the description of the alarm. I think you can do it through VB code. If you look on the Progea site there is an example (AlarmDispatcherBasic).

  • In reply to: Split registers in Variables

    22 March 2013 at 11:02 am #21069
    Maverick
    Participant

    Hi,
    as far as I know you can’t do that with a embedded function in Movicon. I have always used the function VAR00001.0,VAR00001.1, VAR00001.2 because i use that to pack ‘bits’ in a same variable to optimize the communication.
    I think you could create a VB code to extract the information reading it from the resource projectname.movrealtimedb present in the Project Folder.

  • Maverick
    Participant

    Hi,
    as far as I know, there are tow options to manage the Screen appearances.

    The first one is ‘Start Full Screen’ Execution group Project Properties that startup the project in Full Screen mode, therefore the Screen window will be displayed without the title bar.

    Then for each screen you can set the ‘Fit in Window’ Style Screen properties that automatically adapts the Screen’s size to fit  the window containing it, and therefore the screen resolution set in the graphic card.