I/O Drivers
I/O Drivers List for Movicon 11
Listed below are the I/O Drivers that are available and included within the software product
Manufacturer | Protocol | Requirements | Activ. Code | Info |
---|---|---|---|---|
3S Codesys | PLC Handler | CoDeSys Runtime Ver. 2.3, Ver. 3.x | ||
ABB | Modbus RTU | AC31, AC410 and others | ||
ABB | Modbus TCP | AC31, AC410 and others | ||
Allen Bradley | DF1 | PLC-5, SLC-500, MicroLogix, ControlLogix, CompactLogix and FlexLogix | ||
Allen Bradley | EtherNet/IP | PLC-5, SLC-500, MicroLogix, ControlLogix, CompactLogix and FlexLogix | ||
Alstom | IEC-60870-5-104 | Alstom RTU & Devices | * | |
Applicom | Applicom Communication server | PC1000 / PC2000 / PC4000 | ||
April | Modbus RTU | A2000 / 5000 / 7000 / PB80 / 200 / 400 | ||
Axel | Axel LogicLab | LogicLab SoftLogic Runtime | ||
B+R | PVI interface | System 2000 and any other via PVI library | ||
BACNet/IP | BACNet/IP - Annex J | Any standard device compliant Bacnet | * | |
Beckhoff | TwinCAT ADS | TwinCAT softPLC and I/O | ||
Bosch Rexroth | MLPI | Bosch Rexroth device which supports the Motion Logic Programming Interface | ||
CAN Open | CIFX | Profibus DP, Profinet, EtherCAT, PowerLink, CanOpen, Sercos and many other. | ||
Carlo Gavazzi | Modbus RTU | Dupline | ||
Control-Techniques | Modbus TCP/IP + CMP protocol | Control Techniques Modbus TCP supporting Modbus TCP/IP and CMP protocol | ||
Control-Techniques | Modbus RTU + CMP protocol | Control Techniques devices supporting Modbus RTU and CMP protocols | ||
Coster | C-Bus | Coster HVAC Controllers | * | |
CTI | NITP, CAMP, TCP/IP | CTI 2500 Series controllers with Ethernet interface | ||
Texas Instruments | NITP, CAMP, TCP/IP | Ti 505 Plcs | ||
Danfoss | Modbus TCP | Danfoss Control Unit | ||
Echelon | LonWorks | Any LonWorks compatible device | * | |
EL.MO | CEI-ABI protocol specification 79/5 and 79/6 | Elmo devices - Serial CEI-ABI | * | |
EL.MO | CEI-ABI protocol specification 79/5 and 79/6 | Elmo devices - Ethernet CEI ABI | * | |
Elau | Modbus TCP | Elau CNC motion control | ||
Elkron | Digit Serial protocol | Digit Controllers | * | |
Elkron | MP Serial protocol | MP110, MP120 Alarm Central | * | |
Elkron | ELK SirFire on TCP | Elkron FAP 500 control units | * | |
EtherCAT | CIFX | The Hilscher CIFX Card interface supports EtherCAT devices. | ||
Endress + Hauser | Energy Manager RMS621 | * | ||
GE General Electric | SNP-X | Serial protocol for GE PLCs 90 Series, Micro Series | ||
GE General Electric | SRTP2 | Ethernet protocol GE PLCs 90 Series, Micro Series | ||
Guardall | Guardall PS002 serial protocol | PX and QX Series | * | |
Hilscher | CIF 50 | Profibus DP, Profinet, EtherCAT, PowerLink, CanOpen, Sercos and many other. | ||
Hilscher | CIFX | Profibus DP, Profinet, EtherCAT, PowerLink, CanOpen, Sercos and many other. | ||
Hilscher | NETx MPI | Simatic S7-300, S7-400, VIPA Plc | ||
Hilscher | S7 MPI | Simatic S7-300, S7-400, VIPA Plc | ||
Hilscher | NET Link | S7 300 and 400 and VIPA System 200V, 300V, 300S and 500S series | ||
Hitachi | Hitachi serial protocol | H-Series | ||
Yaskawa MP | Yaskawa Ethernet Modbus IEC MP | Yaskawa Robot Controller IEC MP | ||
IEC 60870-5-101 | IEC 60870-5-101 unbalanced serial communication for remote controlled units RTU | Any RTU compliant, connected to a Controlling Station via RS232 or RS485 | * | |
IEC 60870-5-104 | IEC 60870-5-104 over TCP/IP, Client | Any RTU compliant, connected to a Controlling Station via TCP/IP networking | * | |
IEC 60870-5-104 Server | IEC 60870-5-104 over TCP/IP, Server | Any RTU compliant, connected to a Controlling Station via TCP/IP networking | ||
IEC 61850 | IEC 61850 MMS Client | Any IEC 61850 MMS server | * | |
Jetter | JetIPCOM7 | Jetter Controller | * | |
Johnson Controls | System 91 | TC-9100, DX-9100, XTM-105 | * | |
Kernel | Kernel serial protocol | Kernel PLC | ||
Konnex-EIB | Konnex, EIS from 1 to 15 | Any KNX-EIB device | * | |
KW Software | ProConOs | ProConOS SoftPLC | ||
Lenze | Lenze Serial | LecomAB | ||
Mauell | IEC60870-5-104 | Mauell RTU and PLC | * | |
Mitsubishi | Ethernet TCP | PLC MELSEC-Q Series | ||
Mitsubishi | Format 1 with checksum serial protocol | PLC MELSEC-Q Series | ||
Mitsubishi | Ethernet | PLC MELSEC-FX3U | ||
Mitsubishi | Ethernet TCP | PLC Melsec-A series | * | |
Mitsubishi | PTP Serial protocol | PLC MELSEC-FX and MELSEC-FX2N PLCs and compatible | ||
Modbus RTU Master | Modbus RTU/ASCII Slave | Any standard Modbus Master device | ||
Modbus RTU Slave | Modbus RTU/ASCII Master | Any standard Modbus Slave device | ||
Modbus TCP | Modbus TCP-IP client | Any standard Modbus Ethernet server | ||
Moeller | Sucom Serial protocol | PLCs PS4-200, PS300 and PS400 series | ||
Notifier | CEI Protocol Specification 79/5 and 79/6 | Notifier Devices - Serial | * | |
Notifier | CEI Protocol Specification 79/5 and 79/6 | Notifier Devices - Ethernet | * | |
Omron | EtherNet/IP | Omron NJ PLCs | ||
Omron | Fins Ethernet | Omron SYSMAC PLCs | ||
Omron | FINS Serial | Omron SYSMAC PLCs | ||
Ova | Dardo Plus Protocol | Dardo Plus | * | |
Panasonic | MEWTOCOL protocol - serial and Ethernet communication | NAIS PLC FP Series | ||
Phoenix Contact | Interbus | I/O and devices over Interbus | ||
Phoenix contact | PLCI 2K | needs the PLCI software libraries (from PHOENIX CONTACT Software GmbH ) in order to communicate with server devices: "PLCI.dll, NativeMetaAPI.dll, MetaILP64_10.dll and MetaILP32_10.dll | ||
Phoenix contact | PLCI | needs the PLCI software libraries (from PHOENIX CONTACT Software GmbH ) in order to communicate with server devices: "PLCI.dll, NativeMetaAPI.dll, MetaILP64_10.dll and MetaILP32_10.dll | ||
Pixsys | LogicLab SoftLogic Runtime | Pixsys PLC devices | ||
PowerLink | CIFX | The Hilscher CIFX Card interface supports PowerLink devices. | ||
Profibus | CIFX | The Hilscher CIFX Card interface supports Profibus devices. | ||
Profinet | CIFX | The Hilscher CIFX Card interface supports Profinet devices. | ||
Rockwell Automation | DF1 Serial | PLC-5, SLC-500, MicroLogix, ControlLogix, CompactLogix and FlexLogix | ||
Rockwell Automation | EtherNet/IP | PLC-5, SLC-500, MicroLogix, ControlLogix, CompactLogix and FlexLogix | ||
SAIA-Burgess | Saia S-Bus protocol (multi mode) | All PCD series PLCs | ||
SAIA-Burgess | Saia Data Mode protocol | All PCD series PLCs | ||
Sauter | BacNet/IP | Sauter PLCs supporting Bacnet | * | |
Schneider Electric | Modbus TCP | Modicon TSX and any standard Modbus Slave device | ||
Schneider Electric | Modbus RTU/ASCII Master | Modicon TSX and any standard Modbus Slave device | ||
Sercos | CIFX | The Hilscher CIFX Card interface supports Sercos devices. | ||
Schneider Electric | Uni-Telway Slave | Telemecanique PLCs and Uni-Telway protocol compliant devices | ||
Shared Memory | Open I/O data exchange | Customizable Data exchange with active processes through shared memory area | ||
Siemens | SINAUT ST1 | Siemens devices using SinautSt1 protocol | ||
Siemens | AS511 | Simatic-S5 Plcs | ||
Siemens | DK3964R-RK512 | Simatic-S5 Plcs | ||
Siemens | S7-PPI | Simatic-S7-200 | ||
Siemens | S7-MPI | Simatic-S7-300-400 | ||
Siemens | S7-TCP | Simatic-S7-200-300-400-1200-1500 | ||
Siemens | TCP | Simatic-S7-200 | ||
Siemens | TIA PORTAL | Simatic-S7-1200-1500 | ||
Siemens | NET SAPI | All PLC S7 and CP Comm. Boards (CP5611, CP5613, CP5614) | ||
SNMP | Ethernet SNMP | Any SNMP compliant device | * | |
Vipa | Can Bus | Contact the manufacturer for more details | ||
Vipa | S7-TCP Protocol | VIPA System 200V, 300V, 300S | ||
Vipa | S7-MPI Protocol | VIPA PLCs System 100, 200, 300, Speed7; Siemens PLCs S7 300 and 400 series and compatible | ||
Vipa | Profibus DP Slave | Any Profibus DP Master controller | ||
Wago | Modbus RTU | Any RTU controller or remote I/O | ||
Wago | Modbus TCP | Any RTU controller or remote I/O | ||
WITS | WITS Master Serial | devices that support Level 0 of the WITS protocol and transmit solicited data | * | |
MQTT Client | MQTT v3 | support standard MQTT servers (brokers) | ||
MT Connect | MTConnect protocol | The driver has been tested with agents of MAZAK and NH4000 devices. |
If you can’t find your device or your protocol, please contact us! We might be working on it or already available.